2018.08.09 ThomasVer 2018.08.10 0109
1.更改主板工厂生产测试模式流程
2.
----------------------------------------------------------------------------------------------------------------------------------------
2018.08.09 ThomasVer 2018.08.09 0209
1.增加MBUS充电时间为可设置默认2S
2.
----------------------------------------------------------------------------------------------------------------------------------------
2018.01.30 Thomas(Ver 2017.01.30 0108)
1.更改MBUS或者其他任何通讯方式同一块表计抄表失败三次以上之后不再重抄
a)当转换器重启时,每一块表计的抄表失败次数,清零。
b)当某一块表计数据保存有效时间到达之后,清除数据有效标识,抄表失败次数归零。所以当某块表计曾经抄读成功过一次之后,都会在清除数据有效标识
之后,清除抄表失败次数。这块表计获取重抄的机会三次。
2.更改在PLC或者下行抄表端口超过8小时未收到数据则复位转换器。下行端口计数器清零规则
a)抄表成功,更新档案数据时清零。
b)有载波数据时,直接从档案中读取数据成功时计数器清零。
c)开关阀控成功时清零。
3.增加开关阀控功能DLT645 CMD:0x19
4.增加开关阀控调试命令(controlkey 1010234567891100FF或者controlkey 101023456789110000)。
5.增加与无线模块兼容。重新制定水表地址和水表数据645帧读取转换器水表采集器信息645帧水表采集器信道绑定645帧。
6.增加无线模块线程。可以监听无线模块数据。
----------------------------------------------------------------------------------------------------------------------------------------
2017.06.16 ThomasVer 2017.06.16 0101
1.去除LoRa无线部分驱动接收代码
2.优化CMD调试ls功能。
3.更改simulplc命令依据附件多表集中器抄表645帧。
4.添加福建规约645帧识别转发、错误、应答机制。以及福建赛达水表集中器协议创建、识别。
5.增加外部RTC时间管理任务。每隔2 s 读取一次外部时钟时间。更改时间管理结构体存储结构,增加调试命令设置,读取时钟命令。
6.更改LED显示机制。
set_port_prams
根据福建水电气热设备通信地址管理规定 福建龙岩新罗区的水表地址规律如下680210000003
2017.06.20 ThomasVer 2017.06.16 0101
1.更改水表集中器采集数据转换将水表集中器内数据转换成符合645协议 的BCD数据